Home » Wine Analyzers » Receiving Area » BL01 – Grapes Analyzer
BL01 – Grapes Analyzer
Bx of the grapes must after the crusher
DESCRIPTION
The BL-01 system for evaluating must (crushed grapes) on delivery, directly measures the characteristic parameters on the transferring line between the grape crusher and the fermenter. The application of this system is appropriate when crushing is performed batch by batch. The system can handle up to 4 analyers installed in 4 different lines. The parameter detected by the BL-01 is the degrees Brix value while as an option the system can be completed with a pH measurement. In the standard configuration, the measurement is made using a UR-24 refractometer installed on the main piping (diameter 80 or 100 DIN) downline from the crusher, which then transmits the measured values to a control console (PC) connected via a RS485/USB converter. The control console receives the data sent by the in line refractometers (up to 4) and then processes and stores it in a special database and transmits it to the Central Computer. – The control console is usually installed on a platform or box on which a trained operator works, managing all the operations of all the crushers in the winery.
BENEFITS
- Application after the crusher
- 100% in line installation
- Capability to handle up to 4 lines
- Software for data analysis
DOWNLOADS
- Brochure BW [PDF]
- Brochure Oenology – Grading [PDF]
CONTACT US
Application: | Measurement System for evaluating a sample of grape must on delivery, with measurement of parameters Degree and/or pH directly on the de-stemming and crushing line. The System can be configured for the analysis of 1…4 lines. |
Measurement limits/scale | Measurement of concentration: 1.3403…1.3902 nD Automatic conversion of indication in the measurement scales listed below, with limit corresponding to: 5…35 degrees BRIX 4…30 degrees BABO 0…22 degrees ALCOLE 3…20 degrees BAUME’ 3…32 kg/q 20…153 degrees OECHSLE |
Notes: | The comparison in the various scales of measurement refers to the conversion Tables nD/xx ICUMSA (1974). |
Accuracy: | The values given below refer to a standard sucrose solution. 0.3% of Scale Field. Accuracy ±0.10 Brix or equivalent for corresponding scales. |
pH measurement: | 2…14 pH |
Accuracy: |
±0.05 unit of pH |
Product temperature: |
5…45 °C (41…113 °F) Automatic compensation of temperature measured by means of Temperature probes Pt100 made of AISI 316 Stainless steel ¼”, Class “A” in accordance with IEC751. |
Line pressure: |
max. 7 bar (101 psi) at 65 °C (149 °F) |